Epson SD-800 (1.2MB) + SD-700 (1.44MB)
Se under for konfig. av A vs B / 1.2 vs 1.44
3.5" 5.25"
Slot Connector SS1 (1.44Mb) (1.2Mb)
Configuration 1: Upper Drive A A A B
Configuration 2: Upper Drive A B B A
Configuration 3: Lower Drive B A B A
Configuration 4: Lower Drive B H A B
FDD cable (inside PC) 34-pin Drive B 34-pin Drive A
Attach the 4-pin power cable to the rear of the FDD and attach the
34-pin edge connector to the rear of the FDD. When looking at the
rear of the FDD, pin 1 of the connector is to the left. There is a
small slot between pins 4 and 6 on the FDD connector, line up the
cable connector with this slot.
Jumper Configurations
A 1 3 D L R
--- -----------------------
X o o o o o
SS1 X SS2 o o X X o
o o o X X o
--- -----------------------
B 0 2 S H D
Default Jumper Settings
Jumper Definitions
Drive Select:
SS 1 Drive Configuration
A Drive Select A = 5.25
Drive Select B = 3.5"
B Drive Select A = 3.5"
Drive Select B = 5.25
Mode Change (5.25"):
SS 2 Logic
L Low: HIGH mode
High: NORM mode
H Low: NORM mode
High: HIGH mode
Motor Speed in NORM mode (5.25"):
SS 2 Speed
D 300 RPM
S 360 RPM
Do not place jumpers on SS2, pins 0, 1, 2, 3, R, or D.
SS1 Determines the "drive select" for the 3.5" and 5.25" FDD.
In the default position (A) the *A* drive is the 3.5" FDD
**if** the dual drive is in the upper slot of the pc and
uses the FDD connector on the end of the cable (after the
"twist").
If the SS1 jumper is changed to the (B) position, the 5.25"
FDD becomes the *A* drive **if** the dual drive is in the
upper slot of the PC and uses the FDD Connector on the end
of the cable (after the "twist").
SS2 No jumpers are necessary between the 0-1-2-3 jumpers.
The D-S jumper determines the rotational speed of the
5.25" FDD. The default position (S) sets the speed to 360RPM.
The (D) position sets the speed to 300RPM.
The L-H jumper determines the mode of the 5.25" FDD.
The default position (H) defines Low as Norm mode and
High = High mode.